id: idrac
title: Dell iDRAC Monitoring
sidebar_label: Server Monitor
keywords: [open source monitoring tool, open source server Monitoring, Dell iDRAC Monitoring]
---
> Collect and monitor the general performance Metrics of Dell Server using SNMP Protocol.
**Protocol: SNMP**
## Pre-monitoring steps
1. The target Dell server supports the **SNMP protocol**.
2. The **iDRAC** (Integrated Dell Remote Access Controller) has been configured with a network interface, allowing access to the **SNMP port**.
3. **SNMP community string** or **user credentials** have been configured with appropriate **permissions**.
These are basic checks you can follow, and for further details on enabling and configuring SNMP on Dell iDRAC, you can consult the specific user manual of the Dell server.
## Configuration Parameters
| Parameter Name | Parameter Description |
| -------------- |----------------------------------------------------------------------------------------------------------------|
| Target Host | The IPv4, IPv6, or domain name of the monitored peer. Note: without protocol header (e.g., https://, http://). |
| Port | The port number of the server SNMP, default is 161. |
| SNMP Version | Choose between SNMPv1, SNMPv2c, or SNMPv3 |
| SNMP Community | SNMP community for v1 v2c |
| Username | SNMP username for v3 |
| Context Name | SNMP contextName for v3 |
| Auth Password | SNMP authPassword for v3 |
| Auth Encryption| Authentication encryption method for v3 (MD5 or SHA1) |
| Priv Password | SNMP privPassphrase for v3 |
| Priv Encryption| Privacy encryption method for v3 (DES or AES128) |
### Collected Metrics
#### Metric Set: System Status
| Metric Name | Unit | Metric Description |
| ----------------------- | ---- | ------------------------------------------------------------ |
| Global System Status | none | Overall status of the system |
| System LCD Status | none | Status of the system LCD |
| Global Storage Status | none | Overall status of the storage subsystem |
| System Power State | none | Current power state of the system |
| System Power Up Time | day | Time since the system was last powered on |
#### Metric Set: Power Supply
| Metric Name | Unit | Metric Description |
| -------------- | ---- | ------------------------------------------------------------ |
| Index | none | Index of the power supply |
| Name | none | Name/Location of the power supply |
| Wattage | W | Output wattage of the power supply |
| Type | none | Type of the power supply (Linear, Switching, Battery, etc.) |
| Status | none | Current status of the power supply |
#### Metric Set: Cooling Devices
| Metric Name | Unit | Metric Description |
| -------------- | ---- | ------------------------------------------------------------ |
| Index | none | Index of the cooling device |
| Name | none | Name/Location of the cooling device |
| Type | none | Type of the cooling device (Fan, Blower, Heat Pipe, etc.) |
| Reading | RPM | Current rotation per minute reading |
| Status | none | Current status of the cooling device |
#### Metric Set: Temperature Sensors
| Metric Name | Unit | Metric Description |
| -------------- | ---- | ------------------------------------------------------------ |
| Index | none | Index of the temperature sensor |
| Name | none | Name/Location of the temperature sensor |
| Reading | °C | Current temperature reading |
| Status | none | Current status of the temperature sensor |
#### Metric Set: Voltage Sensors
| Metric Name | Unit | Metric Description |
| -------------- | ---- | ------------------------------------------------------------ |
| Index | none | Index of the voltage sensor |
| Name | none | Name/Location of the voltage sensor |
| Reading | V | Current voltage reading |
| Type | none | Type of voltage (3.3V, 5V, 12V, etc.) |
| Status | none | Current status of the voltage sensor |
#### Metric Set: Memory Devices
| Metric Name | Unit | Metric Description |
| -------------- | ---- | ------------------------------------------------------------ |
| Index | none | Index of the memory device |
| Name | none | Name/Location of the memory device |
| Type | none | Type of memory (DDR, DDR2, DDR3, DDR4, etc.) |
| Size | G | Size of the memory device |
| Status | none | Current status of the memory device |
#### Metric Set: Processors
| Metric Name | Unit | Metric Description |
| -------------- | ---- | ------------------------------------------------------------ |
| Index | none | Index of the processor |
| Name | none | Name/Location of the processor |
| Speed | MHz | Current speed of the processor |
| Family | none | Family of the processor (Pentium, Xeon, Core i7, etc.) |
| Status | none | Current status of the processor |