chore: import upstream snapshot with attribution
This commit is contained in:
@@ -0,0 +1,53 @@
|
||||
---
|
||||
id: ipmi
|
||||
title: IPMI2 Monitoring
|
||||
sidebar_label: Server Monitor
|
||||
keywords: [open source monitoring tool, open source server Monitoring, IPMI Monitoring]
|
||||
---
|
||||
|
||||
> Collect and monitor the general performance Metrics of Server using IPMI2.
|
||||
|
||||
**Protocol: IPMI**
|
||||
|
||||
## Pre-monitoring steps
|
||||
|
||||
1. The target server supports the **IPMI2 protocol**.
|
||||
2. The **BMC** (Baseboard Management Controller) has been configured with a network interface, allowing access to the **IPMI port**.
|
||||
3. **User accounts** have been configured, and appropriate **permissions** have been assigned to the accounts.
|
||||
|
||||
These are basic checks you can follow, and for further details on enabling and configuring IPMI over LAN, you can consult the specific user manual of the server manufacturer.
|
||||
|
||||
## Configuration Parameters
|
||||
|
||||
| Parameter Name | Parameter Description |
|
||||
| -------------- |----------------------------------------------------------------------------------------------------------------|
|
||||
| Target Host | The IPv4, IPv6, or domain name of the monitored peer. Note: without protocol header (e.g., https://, http://). |
|
||||
| Port | The port number of the server IPMI over LAN, default is 623. |
|
||||
| Username | IPMI user name |
|
||||
| Password | IPMI password |
|
||||
|
||||
### Collected Metrics
|
||||
|
||||
#### Metric Set: Chassis
|
||||
|
||||
| Metric Name | Unit | Metric Description |
|
||||
| -------------------- | ---- | ------------------------------------------------------------ |
|
||||
| System Power | none | Current Power State. Power is on. |
|
||||
| Power Overload | none | Power overload. System shutdown because of power overload condition. |
|
||||
| Power Interlock | none | Power Interlock. |
|
||||
| Main Power Fault | none | Power fault. Fault detected in main power subsystem. |
|
||||
| Power Control Fault | none | Power control fault. Controller attempted to turn system power on or off, but systemdid not enter desired state. |
|
||||
| Power Restore Policy | none | Power restore policy. |
|
||||
| Last Power Event | none | Last Power Event. |
|
||||
| Cooling/Fan Fault | none | Cooling/fan fault detected. |
|
||||
| Drive Fault | none | Drive Fault. |
|
||||
| Front-Panel Lockout | none | Front Panel Lockout active (power off and reset via chassispush-buttons disabled.) |
|
||||
|
||||
#### Metric Set: Sensor
|
||||
|
||||
| Metric Name | Unit | Metric Description |
|
||||
| -------------- | ---- | ------------------------------------------------------------ |
|
||||
| Sensor ID | none | Sensor ID. |
|
||||
| Entity ID | none | Indicates the physical entity that the sensor is monitoring or is otherwiseassociated with the sensor. |
|
||||
| Sensor Type | none | Sensor Type. |
|
||||
| Sensor Reading | none | Current Sensor Reading. |
|
||||
Reference in New Issue